5 research outputs found

    Characterization and Classification of Adherent Cells in Monolayer Culture using Automated Tracking and Evolutionary Algorithms

    Get PDF
    This paper presents a novel method for tracking and characterizing adherent cells in monolayer culture. A system of cell tracking employing computer vision techniques was applied to time-lapse videos of replicate normal human uro-epithelial cell cultures exposed to different concentrations of adenosine triphosphate (ATP) and a selective purinergic P2X antagonist (PPADS), acquired over a 24 hour period. Subsequent analysis following feature extraction demonstrated the ability of the technique to successfully separate the modulated classes of cell using evolutionary algorithms. Specifically, a Cartesian Genetic Program (CGP) network was evolved that identified average migration speed, in-contact angular velocity, cohesivity and average cell clump size as the principal features contributing to the separation. Our approach not only provides non-biased and parsimonious insight into modulated class behaviors, but can be extracted as mathematical formulae for the parameterization of computational models

    Computational approaches for understanding the diagnosis and treatment of Parkinson's disease

    Get PDF
    This study describes how the application of evolutionary algorithms (EAs) can be used to study motor function in humans with Parkinson’s disease (PD) and in animal models of PD. Human data is obtained using commercially available sensors via a range of non-invasive procedures that follow conventional clinical practice. EAs can then be used to classify human data for a range of uses, including diagnosis and disease monitoring. New results are presented that demonstrate how EAs can also be used to classify fruit flies with and without genetic mutations that cause Parkinson’s by using measurements of the proboscis extension reflex. The case is made for a computational approach that can be applied across human and animal studies of PD and lays the way for evaluation of existing and new drug therapies in a truly objective way

    Measuring self-regulation in everyday life: reliability and validity of smartphone-based experiments in alcohol use disorder

    Get PDF
    Self-regulation, the ability to guide behavior according to one’s goals, plays an integral role in understanding loss of control over unwanted behaviors, for example in alcohol use disorder (AUD). Yet, experimental tasks that measure processes underlying self-regulation are not easy to deploy in contexts where such behaviors usually occur, namely outside the laboratory, and in clinical populations such as people with AUD. Moreover, lab-based tasks have been criticized for poor test–retest reliability and lack of construct validity. Smartphones can be used to deploy tasks in the field, but often require shorter versions of tasks, which may further decrease reliability. Here, we show that combining smartphone-based tasks with joint hierarchical modeling of longitudinal data can overcome at least some of these shortcomings. We test four short smartphone-based tasks outside the laboratory in a large sample (N = 488) of participants with AUD. Although task measures indeed have low reliability when data are analyzed traditionally by modeling each session separately, joint modeling of longitudinal data increases reliability to good and oftentimes excellent levels. We next test the measures’ construct validity and show that extracted latent factors are indeed in line with theoretical accounts of cognitive control and decision-making. Finally, we demonstrate that a resulting cognitive control factor relates to a real-life measure of drinking behavior and yields stronger correlations than single measures based on traditional analyses. Our findings demonstrate how short, smartphone-based task measures, when analyzed with joint hierarchical modeling and latent factor analysis, can overcome frequently reported shortcomings of experimental tasks

    Measuring self-regulation in everyday life: Reliability and validity of smartphone-based experiments in alcohol use disorder

    Get PDF
    Self-regulation, the ability to guide behavior according to one's goals, plays an integral role in understanding loss of control over unwanted behaviors, for example in alcohol use disorder (AUD). Yet, experimental tasks that measure processes underlying self-regulation are not easy to deploy in contexts where such behaviors usually occur, namely outside the laboratory, and in clinical populations such as people with AUD. Moreover, lab-based tasks have been criticized for poor test-retest reliability and lack of construct validity. Smartphones can be used to deploy tasks in the field, but often require shorter versions of tasks, which may further decrease reliability. Here, we show that combining smartphone-based tasks with joint hierarchical modeling of longitudinal data can overcome at least some of these shortcomings. We test four short smartphone-based tasks outside the laboratory in a large sample (N = 488) of participants with AUD. Although task measures indeed have low reliability when data are analyzed traditionally by modeling each session separately, joint modeling of longitudinal data increases reliability to good and oftentimes excellent levels. We next test the measures' construct validity and show that extracted latent factors are indeed in line with theoretical accounts of cognitive control and decision-making. Finally, we demonstrate that a resulting cognitive control factor relates to a real-life measure of drinking behavior and yields stronger correlations than single measures based on traditional analyses. Our findings demonstrate how short, smartphone-based task measures, when analyzed with joint hierarchical modeling and latent factor analysis, can overcome frequently reported shortcomings of experimental tasks
    corecore